R1 - SERIES REGULATORS

SIMPLE
RELIABLE
AFFORDABLE

R1 - SERIES REGULATORS

SIMPLE
RELIABLE
AFFORDABLE

PERFECT FOR
SCUBA
TRAVELLERS

LIGHT AND SIMPLE CONSTRUCTION,
APPRECIATED BY TRAVELLERS AND BUSY DIVE CENTERS

IDEAL REGULATOR FOR WARM WATER DIVING (10°C+)

CERTIFIED ACCORDING TO EN 250A > 10°C NORM

PERFECT FOR
SCUBA
TRAVELLERS

LIGHT AND SIMPLE CONSTRUCTION,
APPRECIATED BY TRAVELLERS AND BUSY DIVE CENTERS

IDEAL REGULATOR FOR WARM WATER DIVING (10°C+)

CERTIFIED ACCORDING TO EN 250A > 10°C NORM

R1 FIRST STAGE SPECIFICATION

  • PISTON REGULATOR
  • 4 LP PORTS
  • 1 HP PORT
  • MAX. OPERATING PRESSURE: 300BAR
  • MATERIAL: MARTIME BRONZE, CHROME COATING
  • WEIGHT: 515 G
  • CERTIFIED ACCORGING TO THE NORM EN 250A > 10°C

REC1 - SECOND
STAGE

SIMPLISTIC DESIGN WITH NO SURPRIZES


LIGHT WEIGHT AND ELEGANT LOOK


SMOOTH BREATHING CONTROL KNOB

REC1 - SECOND
STAGE

SIMPLISTIC DESIGN WITH NO SURPRIZES

LIGHT WEIGHT AND ELEGANT

LOOK SMOOTH BREATHING CONTROL KNOB

REC1 SPECIFICATION

  • MATERIAL: POLYAMIDE
  • WEIGHT: 195 G
  • VENTURI EFFECT CONTROL KNOB
  • WIDE EXHAUST TEE
  • CERTIFIED ACCORGING TO THE NORM EN 250A > 10°C

R1 REC1
RECOMMENDED SETS

PHOTO GALLERY

DEAR DIVERS

 

Due to the pandemic emergency, you will spend the next few days at home with your families.
In these difficult moments we should remember to protect ourselves and our diving equipment.

In upcoming days we will not be able to enjoy our regular diving activities. If you have used your diving equipment recently, it is imperative that you subject it to proper disinfection.

This applies particularly to:

  • II nd stage regulators,
  • masks,
  • snorkels,
  • inflators,
  • SMB inflation outlets

All the above elements can be disinfected in a very simple way.

DISINFECTION

  1. Diving equipment should be immersed in ethyl alcohol (this may be rectified spirit) for 30 minutes. The alcohol may be diluted with boiled water (in room temperature) and/or hydrogen peroxide. It is recommended that the solution keeps minimum of 60% pure alcohol. Attention! Do not use ultrasonic cleaners for this disinfection. The alcohol can rinse out lubricants from important elements of the 2nd stage regulators.
  2. We would like to encourage you to prepare a homemade disinfectant recommended by the WHO (link). This liquid can be used for everyday use.The recipe for this disinfectant is as follows: – 100ml ethyl alcohol (spirit), – 15ml of hydrogen peroxide, – 5ml of glycerine or aloe vera gel, – 50ml of boiled water (in room temperature).

PRECAUTIONS

We all hope that the situation will improve quickly and allow us to go diving again – at least in local waters.
If it will be the case, we encourage you to temporarily modify the procedures which involve any contact with the saliva of other people.

  • During the buddy-checks, present the equipment functioning at distance
    (the partner observes but does not check the regulator by taking any test breaths).
  • Do not rent/borrow a diving mask without prior disinfection.
  • Resign from “out of gas” situation exercises.
  • In a real “out of gas” situation follow the normal safety procedures. After the safe ascent, pay attention to the equipment used by the receiver, do not reuse it and subject it to full disinfection as soon as possible.

We hope that the coronavirus pandemic will be stopped shortly.
Looking forward to meet you soon at our favourite diving spots!

Best regards

Tecline Team